There is a simple reason why we are one of the few specialists today for panels as well as for cold room, industrial and agricultural hall construction: our employees. The enthusiasm for our work and the responsibility we take on, our appreciation above all for our customers and a handshake quality that creates trust - all these values drive us and at the same time reflect the soul of the BRUCHA b... voir plusrand. ... voir moins
Contact commercial
Pour voir les informations concernant le contact commercial, vous devez d'abord vous inscrire en cliquant sur ce Lien
Catalogue
Pour voir les informations concernant le contact commercial, vous devez d'abord vous inscrire en cliquant sur ce Lien
Brucha acoustic wall panel
Sélectionnez le format souhaité et cliquez sur le bouton de téléchargement
Partager la page
Main material | Laine minérale |
Secondary material | Acier |
Designed in | Autriche |
Manufactured in | Autriche |
Exterior
•Exposed side 25 μm polyester coating with a PVC protective film (protects against solar radiation). The film must be removed no later than 10 weeks after the production date (visible on the longitudinal panel seam).
•Profile 1 - 6
•Metal gauge: 0.6 mm (smaller metal gauge on request)
Interior
•Exposed side 25 μm polyester coating with a PVC protective film (protects against solar radiation). The film must be removed no later than 10 weeks after the production date (visible on the longitudinal panel seam).
•Profile 2
•Hole proportion: 32.5 %
•Bore diameter: 3 mm round bore, offset
•Holes: DIN RV 3-5 (R3T5) (730-000)
•Metal gauge: 0.6 mm (smaller metal gauge on request)
Insulation core
•Structural, web-oriented mineral fibre wool
•Shear resistant bond with sheet steel covers
•Density approx. 120 kg/m³, 140 kg/m³ available on request
Panel connection
•Tongue groove interconnect; panels interlink precisely with no thermal bridge.
Vapour diffusion
• Due to the vapour permeable inside cover, the use as an exterior wall for wet rooms and heated buildings is only conditionally possible, or not recommended.
Independent monitoring
•National and international tests, quality standards
EXTERIOR:
• Exposed side 25 μm polyester coating with a PVC protective film (protects
against solar radiation). The film must be removed no later than 10 weeks after
the production date (visible on the longitudinal joint of the panel).
• Profile 1 = Standard, for other profiles see WP-A profiles
• Metal gauge: 0.6 mm (smaller metal gauge on request)
INTERIOR:
• Exposed side 25 μm polyester coating with a PVC protective film (protects
against solar radiation). The film must be removed no later than 10 weeks after
the production date (visible on the longitudinal joint of the panel).
• Profile 2
• Hole proportion: 32.5 %
• Bore diameter: 3 mm round bore, offset (5 mm distance)
• Holes: DIN RV 3-5 (R3T5) (730-000)
• Metal gauge: 0.6 mm (smaller metal gauge on request)
INSULATION CORE:
• Structural, web-oriented mineral fibre wool
• Securely attached to the sheet steel shell
• Density approx. 120 kg/m³, 140 kg/m³ available on request
• Mat: glass fibre mat SM60/10 as trickle protection
FIRE BEHAVIOUR:
• In accordance with EN 13501-1, Euroclass A2s1d0, non-combustible
STANDARD COLORS:
• In accordance with BASIC colour range
PANEL CONNECTION:
• Tongue and groove system in which the panels interlink precisely with no
thermal bridge.
VAPOUR DIFFUSION:
• For use as an exterior wall in heated buildings - due to the vapour-permeable
inside cover - it is mandatory to obtain technical clarification from a building
physicist in advance.
PANEL INSTALLATION: • When working with our products, please follow our installation guidelines at
www.brucha.com/downloads.
Standard DESIGN AND SURFACES
Coil-coated, hot-dip galvanised steel sheet
Concealed mounting
Thickness: 60 mm - 240 mm
Manufactured lenghts: max. 15,60m (extra-long transport of 13,6m)
Sound insulation: ca. 32 dB (frequency dependet)
Classification IFC | Mur |
Nom UNSPSC | Wall finishing materials |
Code UNSPSC | 301615 |
Uniclass 1.4 Code | L5161 |
Uniclass 1.4 Description | Wall panelling |
This product is available in:
Andorre Albanie Autriche Åland Bosnie-Herzégovine Belgique Bulgarie Biélorussie Suisse Chypre République tchèque Allemagne Danemark Estonie Espagne Finlande Îles Féroé France Royaume-Uni Guernesey Gibraltar Grèce Croatie Hongrie Irlande Île de Man Islande Italie Jersey Liechtenstein Lituanie Luxembourg Lettonie Monaco Moldavie Monténégro Macédoine du Nord Malte Pays-Bas Norvège Pologne Portugal Roumanie Serbie Russie Suède Slovénie Svalbard et Jan Mayen Slovaquie Saint-Marin Ukraine Vatican
Pour voir les informations sur l’entreprise d’installation, veuillez vous inscrire en cliquant dessus Lien
Product url | https://www.brucha.com |
Installation instruction | https://www.bruchapaneel.com/en/services/downloads.html |
Product certification | https://www.bruchapaneel.com/services/zertifikate.html |
Technical description | https://www.bruchapaneel.com/en/products/wallfacade/fire-protection-wallfacade/Panels/entry/show/bruchapaneel-wp-a.html |