Width | 7500 |
Height | 8500 |
Designed in | Netherlands |
Manufactured in | Netherlands |
EW30/EW60 Fire-resistant, double-walled rolling shutter .
- 90 or 120 minutes of fire resistance
- EW classification (standard EN 1634-1)
- Physical fire separation
- Suitable for airports, retail sector and industry, among others
- Gravity Fail Safe - GFS
- Various operational options
- Easy to use and maintain
The primary aim of a fire-resistant rolling door is to protect people and property by preventing the spread of fire. Firelock Radiation fire-resistant rolling doors are connected to the fire alarm system. When an alarm has sounded, the doors close and form a physical barrier. The Firelock Radiation rolling doors are constructed of a double-walled galvanised steel profile filled with insulating rock wool.
FAIL SAFE
Firelock Radiation fire-resistant rolling doors are equipped with an external Gravity Fail Safe (GFS) chain drive. In the event of power failure, the rolling doors automatically close via an internal electromagnetic clutch.
STANDARD MODEL
- Firelock Smart Control control box for operation and signals.
- Push button or key switch for manual operation.
- Gravity Fail Safe (GFS) motor
- 24V emergency power batteries. In the event of power failure, the rolling door closes after a pre-set period or after a fire alarm.
- Safety braking device, to insure a controlled descent.
- Connection to the fire alarm system.
OPTIONS
- Safety bar
- Rolled door enclosed in housing
- Motor enclosed in housing
- Smoke and temperature sensors for autonomous operation without fire alarm system
- Galvanization or powder-coating of side guides, roller shutter and console
- Upper roll on steel sheet consoles or on steel UNP consoles
STANDARD SPECIFICATIONS
- Installation: On the wall or on the ceiling.
- Application: Airports, retail sector, food processing, petrochemical sector, metro stations, storage units, etc.
- Fire resistance: Tested according to standard EN 1634-1. Fire resistance classes EW90 and EW120.
- Max. dimensions: 10,000 x 7,500 mm (wxh). Other dimensions upon request. No limitation on maximum opening.
- Material: Double-walled, hot-dip galvanised steel, reinforced and insulated slats.
- Slat dimensions: 22 x 100 mm (d x h)
- Metal thickness: 0.8 mm
- Weight: approx. 30 kg/m².
- Fall protection: Standard installation according to standards EN 12604 and EN 12605.
- Side guides: 100 mm wide, galvanised steel profiles.
- Bottom beam: Steel U-profile, optionally provided with safety device
This product is available in:
Angola Burkina Faso Burundi Benin Botswana Democratic Republic of the Congo Central African Republic Republic of the Congo Côte d'Ivoire Cameroon Cape Verde Djibouti Algeria Western Sahara Eritrea Ethiopia Gabon Ghana The Gambia Guinea Equatorial Guinea Guinea-Bissau Kenya Comoros Liberia Lesotho Libya Morocco Madagascar Mali Mauritania Mauritius Malawi Mozambique Namibia Niger Nigeria Reunion Rwanda Seychelles Sudan Saint Helena Sierra Leone Senegal Somalia South Sudan São Tomé and Príncipe Eswatini Chad Togo Tunisia Tanzania Uganda Mayotte South Africa Zambia Zimbabwe
Antarctica Bouvet Island South Georgia and the South Sandwich Islands Heard Island and McDonald Islands French Southern and Antarctic Lands
Armenia Azerbaijan Bangladesh Brunei Bhutan Cocos (Keeling) Islands China Christmas Island Georgia Hong Kong Indonesia India British Indian Ocean Territory Japan Kyrgyzstan Cambodia North Korea South Korea Kazakhstan Laos Sri Lanka Myanmar (Burma) Mongolia Macau Maldives Malaysia Nepal Philippines Pakistan Singapore Thailand Tajikistan Turkmenistan Taiwan Uzbekistan Vietnam
Andorra Albania Austria Åland Islands Bosnia and Herzegovina Belgium Bulgaria Belarus Switzerland Cyprus Czech Republic Germany Denmark Estonia Spain Finland Faroe Islands France United Kingdom Guernsey Gibraltar Greece Croatia Hungary Ireland Isle of Man Iceland Italy Jersey Liechtenstein Lithuania Luxembourg Latvia Monaco Moldova Montenegro North Macedonia Malta Netherlands Norway Poland Portugal Romania Serbia Russia Sweden Slovenia Svalbard and Jan Mayen Slovakia San Marino Ukraine Vatican City
United Arab Emirates Afghanistan Bahrain Egypt Israel Iraq Iran Jordan Kuwait Lebanon Oman Palestine Qatar Saudi Arabia Syria Türkiye Yemen
Antigua and Barbuda Anguilla Aruba Barbados Saint-Barthélemy Bermuda Caribbean Netherlands The Bahamas Belize Canada Costa Rica Cuba Curaçao Dominica Dominican Republic Grenada Greenland Guadeloupe Guatemala Honduras Haiti Jamaica Saint Kitts and Nevis Cayman Islands Saint Lucia Collectivity of Saint Martin Martinique Montserrat Mexico Nicaragua Panama Saint Pierre and Miquelon Puerto Rico El Salvador Sint Maarten Turks and Caicos Islands Trinidad and Tobago United States Saint Vincent and the Grenadines British Virgin Islands U.S. Virgin Islands
American Samoa Australia Cook Islands Fiji Federated States of Micronesia Guam Kiribati Marshall Islands Northern Mariana Islands New Caledonia Norfolk Island Nauru Niue New Zealand French Polynesia Papua New Guinea Pitcairn Islands Palau Solomon Islands Tokelau Timor-Leste Tonga Tuvalu United States Minor Outlying Islands Vanuatu Wallis and Futuna Samoa
Argentina Bolivia Brazil Chile Colombia Ecuador Falkland Islands (Islas Malvinas) French Guiana Guyana Peru Paraguay Suriname Uruguay Venezuela
To see the installation company information, please register first by clicking on this Link